Recommended Conferences

PHYSIOTHERAPY 2022

Paris, France
Related Subjects
 

Accuracy and repeatability of joint angles measured using a single camera markerless motion capture system

Author(s): Schmitz A, Ye M2, Shapiro R3, Yang R2, Noehren B4

Abstract

Markerless motion capture systems have developed in an effort to evaluate human movement in a natural setting. However, the accuracy and reliability of these systems remain understudied. Therefore, the goals of this study were to quantify the accuracy and repeatability of joint angles using a single camera markerless motion capture system and to compare the markerless system performance with that of a marker-based system. A jig was placed in multiple static postures with marker trajectories collected using a ten camera motion analysis system. Depth and color image data were simultaneously collected from a single Microsoft Kinect camera, which was subsequently used to calculate virtual marker trajectories. A digital inclinometer provided a measure of ground-truth for sagittal and frontal plane joint angles. Joint angles were calculated with marker data from both motion capture systems using successive body-fixed rotations. The sagittal and frontal plane joint angles calculated from the marker-based and markerless system agreed with inclinometer measurements by <0.5°. The systems agreed with each other by <0.5° for sagittal and frontal plane joint angles and <2° for transverse plane rotation. Both systems showed a coefficient of reliability <0.5° for all angles. These results illustrate the feasibility of a single camera markerless motion capture system to accurately measure lower extremity kinematics and provide a first step in using this technology to discern clinically relevant differences in the joint kinematics of patient populations.

Similar Articles

Studies of human locomotion: past, present and future

Author(s): Andriacchi TP, Alexander EJ

Calibration of the "Flock of Birds" electromagnetic tracking device and its application in shoulder motion studies

Author(s): Meskers CG, Fraterman H, van der Helm FC, Vermeulen HM, Rozing PM

Dynamic measurements of three-dimensional scapular kinematics: a validation study

Author(s): Karduna AR, McClure PW, Michener LA, Sennett B

Human movement analysis using stereophotogrammetry

Author(s): Leardini A, Chiari L, Della Croce U, Cappozzo A

Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo

Author(s): Benoit DL, Ramsey DK, Lamontagne M, Xu L, Wretenberg P, et al.

Human movement analysis using stereophotogrammetry

Author(s): Della Croce U, Leardini A, Chiari L, Cappozzo A

Human movement analysis using stereophotogrammetry

Author(s): Cappozzo A, Della Croce U, Leardini A, Chiari L

Differences in normal and perturbed walking kinematics between male and female athletes

Author(s): Hurd WJ, Chmielewski TL, Axe MJ, Davis I, Snyder-Mackler L

Direct 3-dimensional measurement of scapular kinematics during dynamic movements in vivo

Author(s): McClure PW, Michener LA, Sennett BJ, Karduna AR

Evaluation and management of scapular dysfunction

Author(s): McClure P, Greenberg E, Kareha S

Kinematic analysis of a multi-segment foot model for research and clinical applications: a repeatability analysis

Author(s): Carson MC, Harrington ME, Thompson N, O'Connor JJ, Theologis TN

An anatomically based protocol for the description of foot segment kinematics during gait

Author(s): Leardini A, Benedetti MG, Catani F, Simoncini L, Giannini S

A procedure to validate three-dimensional motion assessment systems

Author(s): DeLuzio KJ, Wyss UP, Li J, Costigan PA

Scapular kinematics during humeral elevation in adults and children

Author(s): Dayanidhi S, Orlin M, Kozin S, Duff S, Karduna A

Test-retest reliability of 3D kinematic gait variables in hip osteoarthritis patients

Author(s): Laroche D, Duval A, Morisset C, Beis JN, d'Athis P, et al.

Anatomy and biomechanics of the shoulder

Author(s): Halder AM, Itoi E, An KN

Shoulder kinematics in subjects with frozen shoulder

Author(s): Rundquist PJ, Anderson DD, Guanche CA, Ludewig PM

Three-dimensional kinematics of the lower limbs in hip osteoarthritis during walking

Author(s): Ornetti P, Laroche D, Morisset C, Beis JN, Tavernier C, et al.

Gait analysis 6 and 12 months after anterior cruciate ligament reconstruction surgery

Author(s): Hooper DM, Morrissey MC, Drechsler WI, Clark NC, Coutts FJ, et al.

Foot kinematics in people with medial compartment knee osteoarthritis

Author(s): Levinger P, Menz HB, Morrow AD, Feller JA, Bartlett JR, et al.

Gender differences in lower extremity mechanics during running

Author(s): Ferber R, Davis IM, Williams DS 3rd

Gait and neuromuscular asymmetries after acute anterior cruciate ligament rupture

Author(s): Gardinier ES, Manal K, Buchanan TS, Snyder-Mackler L

Human movement analysis using stereophotogrammetry

Author(s): Chiari L, Della Croce U, Leardini A, Cappozzo A